<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Russian Journal of Dentistry</journal-id><journal-title-group><journal-title xml:lang="en">Russian Journal of Dentistry</journal-title><trans-title-group xml:lang="ru"><trans-title>Российский стоматологический журнал</trans-title></trans-title-group></journal-title-group><issn publication-format="print">1728-2802</issn><issn publication-format="electronic">2413-2934</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">716142</article-id><article-id pub-id-type="doi">10.17816/dent716142</article-id><article-id pub-id-type="edn">UPJEVY</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Original Study Articles</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Оригинальные исследования</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Reproducibility of occlusal contacts in CAD/CAM splint fabrication: analysis using Hausdorff distance and clinical validation: a cross-sectional study</article-title><trans-title-group xml:lang="ru"><trans-title>Воспроизводимость окклюзионных контактов при изготовлении шин в CAD/CAM: анализ с помощью метрики Хаусдорфа и клиническая валидация: одномоментное исследование</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-1096-7568</contrib-id><contrib-id contrib-id-type="spin">4724-5883</contrib-id><name-alternatives><name xml:lang="en"><surname>Erokhin</surname><given-names>Vladislav A.</given-names></name><name xml:lang="ru"><surname>Ерохин</surname><given-names>Владислав Алексеевич</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><email>vladalex.171097@mail.ru</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0009-0000-2390-0413</contrib-id><contrib-id contrib-id-type="spin">3243-8270</contrib-id><name-alternatives><name xml:lang="en"><surname>Kovgan</surname><given-names>Dmitry S.</given-names></name><name xml:lang="ru"><surname>Ковган</surname><given-names>Дмитрий Сергеевич</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><email>megaspayn@mail.ru</email><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-7221-7976</contrib-id><contrib-id contrib-id-type="spin">5951-4659</contrib-id><name-alternatives><name xml:lang="en"><surname>Trunin</surname><given-names>Dmitry A.</given-names></name><name xml:lang="ru"><surname>Трунин</surname><given-names>Дмитрий Александрович</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MD, Dr. Sci. (Medicine), Professor</p></bio><bio xml:lang="ru"><p>д-р мед. наук, профессор</p></bio><email>trunin-027933@yandex.ru</email><xref ref-type="aff" rid="aff3"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2885-3657</contrib-id><contrib-id contrib-id-type="spin">8797-6513</contrib-id><name-alternatives><name xml:lang="en"><surname>Parunov</surname><given-names>Vitaly A.</given-names></name><name xml:lang="ru"><surname>Парунов</surname><given-names>Виталий Анатольевич</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MD, Dr. Sci. (Medicine), Professor</p></bio><bio xml:lang="ru"><p>д-р мед. наук, профессор</p></bio><email>vparunov@mail.ru</email><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-0437-1290</contrib-id><contrib-id contrib-id-type="spin">9363-9779</contrib-id><name-alternatives><name xml:lang="en"><surname>Saveliev</surname><given-names>Vasily V.</given-names></name><name xml:lang="ru"><surname>Савельев</surname><given-names>Василий Владимирович</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MD, Cand. Sci. (Medicine)</p></bio><bio xml:lang="ru"><p>канд. мед. наук</p></bio><email>bazilsav@gmail.com</email><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Samara State Medical University</institution></aff><aff><institution xml:lang="kk"></institution></aff><aff><institution xml:lang="pt"></institution></aff><aff><institution xml:lang="ru">Самарский государственный медицинский университет</institution></aff><aff><institution xml:lang="zh"></institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">Peoples' Friendship University of Russia</institution></aff><aff><institution xml:lang="ru">Российский университет дружбы народов имени Патриса Лумумбы</institution></aff></aff-alternatives><aff-alternatives id="aff3"><aff><institution xml:lang="en">Samara State Medical University</institution></aff><aff><institution xml:lang="ru">Самарский государственный медицинский университет</institution></aff></aff-alternatives><pub-date date-type="preprint" iso-8601-date="2026-08-05" publication-format="electronic"><day>05</day><month>08</month><year>2026</year></pub-date><pub-date date-type="pub" iso-8601-date="2026-09-21" publication-format="electronic"><day>21</day><month>09</month><year>2026</year></pub-date><volume>30</volume><issue>3</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>202</fpage><lpage>213</lpage><history><date date-type="received" iso-8601-date="2026-07-08"><day>08</day><month>07</month><year>2026</year></date><date date-type="accepted" iso-8601-date="2026-07-22"><day>22</day><month>07</month><year>2026</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2026, Eco-Vector</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2026, Эко-Вектор</copyright-statement><copyright-year>2026</copyright-year><copyright-holder xml:lang="en">Eco-Vector</copyright-holder><copyright-holder xml:lang="ru">Эко-Вектор</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/" start_date="2029-09-21"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">https://eco-vector.com/for_authors.php#07</ali:license_ref></license></permissions><self-uri xlink:href="https://rjdentistry.com/1728-2802/article/view/716142">https://rjdentistry.com/1728-2802/article/view/716142</self-uri><abstract xml:lang="en"><p><bold>BACKGROUND:</bold> Despite the widespread adoption of CAD/CAM technologies for occlusal splint fabrication, the degree of agreement between virtually calculated occlusal contacts and the actual clinical contact pattern remains insufficiently investigated. The accuracy of occlusal transfer may be influenced not only by digital design algorithms but also by CAM manufacturing stages, post-processing procedures, and clinical adaptation of the appliance. Quantitative criteria for comprehensive evaluation of occlusal contact reproducibility throughout all stages of the digital workflow are still lacking.</p> <p><bold>AIM:</bold> To evaluate the accuracy of occlusal contact transfer in digitally designed occlusal splints by sequentially comparing virtual data with the geometry of the fabricated devices and clinical contacts in the oral cavity.</p> <p><bold>METHODS:</bold> A cross-sectional comparative clinical and laboratory study was conducted, including 20 clinical cases. For each case, two occlusal splints were fabricated (Avantis 3D and Exocad), totaling 40 appliances. Original STL models were compared with STL models of the splints after milling and scanning, and virtual contact maps were compared with clinical occlusal contacts recorded using 8- and 40-μm articulating film. Geometric deviations between CAD and CAM models were assessed using the Hausdorff distance, with independent verification in GOM Inspect. Localization and intensity of occlusal contacts were additionally analyzed according to functional zones of the dental arch. Statistical analysis was performed using the Pearson's chi-square test and Cohen's kappa coefficient.</p> <p><bold>RESULTS:</bold> Virtual contact maps of Avantis 3D and Exocad coincided in 16 of 20 paired comparisons (80%). During clinical validation, the agreement between virtual and actual contacts was 70% for Avantis 3D and 85% for Exocad; no statistically significant differences were found between the systems (χ<sup>2</sup> = 1.80; <italic>p</italic> = 0.180), and the kappa coefficient was κ = 0.41. The most pronounced discrepancies in contact localization were observed in the anterior segment of the dental arch, whereas the highest reproducibility was maintained in the molar segments. Analysis of contact intensity showed that the lowest agreement indices were recorded in the caninepremolar segments. According to Hausdorff analysis, when virtual and clinical contacts agreed in ≥ 80% of cases, maximum deviations in the occlusal zone did not exceed 50–70 μm, whereas in cases of clinical discrepancies, the 95th percentile was 132 ± 24 μm, exceeding the threshold value of 100 μm.</p> <p><bold>CONCLUSION:</bold> The accuracy of occlusal contact transfer in digitally fabricated splints is determined by the combined influence of CAD design, CAM manufacturing, and clinical implementation stages. The proposed comprehensive approach, integrating clinical validation, zonal contact analysis, and Hausdorff-based metric assessment, enables objective quality control of the digital protocol and identification of error accumulation stages. Study limitations include the relatively small sample size and single-center design, warranting further validation in larger clinical cohorts.</p></abstract><trans-abstract xml:lang="ru"><p><bold>Обоснование. </bold>Несмотря на широкое внедрение CAD/CAM-технологий при изготовлении окклюзионных сплинтов, степень соответствия виртуально рассчитанных окклюзионных контактов фактической клинической картине остаётся недостаточно изученной. На точность передачи окклюзии могут влиять не только алгоритмы цифрового моделирования, но и этапы CAM-изготовления, постобработки и клинической адаптации конструкции. Отсутствуют количественные критерии, позволяющие комплексно оценить воспроизводимость окклюзионных контактов на всех этапах цифрового протокола.</p> <p><bold>Цель. </bold>Оценить точность передачи окклюзионных контактов сплинтов, смоделированных цифровыми системами проектирования, путём последовательного сопоставления виртуальных данных с геометрией изготовленных изделий и клиническими контактами в полости рта.</p> <p><bold>Методы. </bold>Проведено одномоментное сравнительное клинико-лабораторное исследование, включившее 20 клинических случаев, для каждого из которых были изготовлены два окклюзионных сплинта (Avantis 3D и Exocad), всего 40 изделий. Исходные STL-модели сравнивали с STL-моделями сплинтов после фрезерования и сканирования, а виртуальные контактные карты — с клиническими окклюзионными контактами, зарегистрированными артикуляционной плёнкой толщиной 8 и 40 мкм. Геометрические отклонения между CAD- и CAM-моделями определяли по метрике Хаусдорфа с независимой верификацией в GOM Inspect. Дополнительно анализировали локализацию и интенсивность окклюзионных контактов по функциональным зонам зубного ряда. Для статистического анализа использовали χ<sup>2</sup>-критерий Пирсона и коэффициент согласия Каппа.</p> <p><bold>Результаты. </bold>Виртуальные контактные карты Avantis 3D и Exocad совпадали в 16 из 20 сопоставляемых пар (80%). При клинической валидации совпадение виртуальных и фактических контактов составило 70% для Avantis 3D и 85% — для Exocad; статистически значимых различий между системами не выявлено (χ<sup>2</sup> = 1,80; <italic>p</italic> = 0,180), коэффициент согласия составил κ = 0,41. Наиболее выраженные расхождения локализации контактов наблюдались в переднем отделе зубного ряда, тогда как максимальная воспроизводимость сохранялась в молярных сегментах. Анализ интенсивности контактов показал, что наиболее низкие значения индекса соответствия регистрировались в клыково-премолярных сегментах. По данным Хаусдорф-анализа, при совпадении виртуальных и клинических контактов ≥ 80% максимальные отклонения в окклюзионной зоне не превышали 50–70 мкм, тогда как при клинических несовпадениях 95-й перцентиль составлял 132 ± 24 мкм и превышал пороговое значение 100 мкм.</p> <p><bold>Заключение. </bold>Точность передачи окклюзионных контактов при цифровом изготовлении сплинтов определяется совокупным влиянием этапов CAD-моделирования, CAM-производства и клинической реализации. Предложенный комплексный подход, объединяющий клиническую валидацию, зональный анализ контактов и метрическую оценку по Хаусдорфу, позволяет объективизировать контроль качества цифрового протокола и выявлять этапы формирования погрешности. Ограничениями исследования являются небольшой объём выборки и одноцентровый дизайн, что требует дальнейшей проверки полученных результатов на более крупном клиническом материале.</p></trans-abstract><kwd-group xml:lang="en"><kwd>occlusal splints</kwd><kwd>occlusal contacts</kwd><kwd>digital dentistry</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>окклюзионные шины</kwd><kwd>окклюзионные контакты</kwd><kwd>цифровая стоматология</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Wright EF, Klasser GD. Orofacial pain: Guidelines for Assessment, Diagnosis, and Management. Chicago: Quintessence Publishing; 2019. 312 p.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Edelhoff D, Schweiger J, Prandtner O, et al. CAD/CAM splints for the functional and esthetic evaluation of newly defined occlusal dimensions. Quintessence Int. 2017;48(3):181–191. doi: 10.3290/j.qi.a37641</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Shopova D, Bozhkova T, Yordanova S, Yordanova M. Case report: Digital analysis of occlusion with T-Scan Novus in occlusal splint treatment for a patient with bruxism. F1000Res. 2022;10:915. doi: 10.12688/f1000research.72951.2 EDN: XLWQKQ</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Blasi A, Henarejos-Domingo V, Palacios-Bañuelos R, et al. CAD-CAM and analog occlusal splints comparison based on the amount of occlusal adjustments. 3D analysis of the volumetric changes: A pilot study. J Esthet Restor Dent. 2023;35(8):1271–1278. doi: 10.1111/jerd.13080 EDN: EVWOCH</mixed-citation></ref><ref id="B5"><label>5.</label><mixed-citation>Muresanu SA, Hedesiu M, Dinu C, et al. Digital occlusal splints for temporomandibular joint disorders: a systematic review. Romanian Journal of Stomatology. 2022;68(3):127–134. doi: 10.37897/RJS.2022.3.1 EDN: THCPDY</mixed-citation></ref><ref id="B6"><label>6.</label><mixed-citation>Almansour FW, Alshammari K, Mohammed Alhajri D, et al. Digital versus conventional splints in patients with temporomandibular disorders: a systematic review and meta-analysis of randomized controlled trials. Cureus. 2026;18(3):e105977. doi: 10.7759/cureus.105977 EDN: EUMQPJ</mixed-citation></ref><ref id="B7"><label>7.</label><mixed-citation>Torné-Durán S, Marco-Martínez L, Serrano-Belmonte I. Pilot clinical comparison of three occlusal splint fabrication techniques: A preliminary study. Sci Rep. 2026;16:2963. doi: 10.1038/s41598-025-32846-6 EDN: GCQEMN</mixed-citation></ref><ref id="B8"><label>8.</label><mixed-citation>Ryakhovsky AN. Clinical experience in the splint therapy of patients with tmj dysfunction. Part II. Clinical Dentistry (Russia). 2025;28(4):102–108. doi: 10.37988/1811-153X_2025_4_102 EDN: STOPPQ</mixed-citation></ref><ref id="B9"><label>9.</label><mixed-citation>Ryakhovsky AN. Clinical experience in the splint therapy of patients with tmj dysfunction. Part i. Diagnostics. Clinical Dentistry (Russia). 2025;28(3):16–20. doi: 10.37988/1811-153X_2025_3_16 EDN: WSGNNN</mixed-citation></ref><ref id="B10"><label>10.</label><mixed-citation>Wu A, Li P, Bakker AD, et al. Accuracy of CAD/CAM-based subtractive versus digital light processing fabricated mono-block splints for TMD management: An in vitro study. J Dent. 2025;163:106136. doi: 10.1016/j.jdent.2025.106136 EDN: WGJUQF</mixed-citation></ref><ref id="B11"><label>11.</label><mixed-citation>Reich S, Berndt S, Kühne C, Herstell H. Accuracy of 3D-printed occlusal devices of different volumes using a digital light processing printer. Appl Sci. 2022;12(3):1576. doi: 10.3390/app12031576 EDN: ENFFCA</mixed-citation></ref></ref-list></back></article>
